DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
Managing Disk Drives and Enclosures
G.1.6 Blinking a Drive LED
You can blink the LED on a specific drive one of two ways:
From the Drive Utilities Menu (only works for a single drive; see
below)
• From the Display Drives list when you add a pool spare or display all
drives (works for multiple drives). Select the drive and press <B>.
Press <B> again to stop the blinking.
To blink a drive LED from the Drive Utilities Menu:
1. From the System Menu, select Utilities Menu and press <Enter>.
The Utilities Menu displays.
2. Select Drive Utilities Menu and press <Enter>. The Drive Utilities
Menu displays.
3. Select Blink Drive LED and press <Enter>. The Select Drive screen
displays.
4. Select the drive you want and press <Enter>. The drive continues
blinking its LED until you do one of the following:
- Press <Esc> before the Disk Array Administrator times out.
- Repeat the blink LED command, which toggles the blink LED
command off.
5. Press <Esc> to stop blinking the LED.
G.1.7 Taking Down a Drive
C
AUTION
!
This function is only for testing and could result in data loss.
It should not be used in normal operation.
The Down Drive function sets the status of a drive in a fault-tolerant
array to down. This forces the EF2800 to remove it from the array and
marks the array as critical. At this point, you will be unable to take
down any additional drives in the array.
If you have a properly sized dedicated or pool spare, this will cause a
reconstruct on the affected array. For more information, see section
D.2.5, "Reconstructing an Array" on page 227.